{"id":28349,"date":"2026-07-28T14:02:05","date_gmt":"2026-07-28T11:02:05","guid":{"rendered":"https:\/\/apellaser.ro\/?post_type=product&#038;p=28349"},"modified":"2026-07-28T14:03:41","modified_gmt":"2026-07-28T11:03:41","slug":"echo-b-o2-automatic-oxygen-analyser","status":"publish","type":"product","link":"https:\/\/apellaser.ro\/en\/product\/echo-b-o2-automatic-oxygen-analyser\/","title":{"rendered":"ECHO B-O2 automatic oxygen analyser"},"content":{"rendered":"<h2><span lang=\"EN-US\">ECHO B-O2 automatic oxygen analyser for pharmaceutical blister packs<\/span><\/h2>\n<p>The system can analyse 1\u20136 blisters and up to 72 points in one serial measurement. Optical measurement consumes no oxygen and requires no sample extraction. Precise positioning, automatic calibration and statistical reporting reduce operator influence in quality control and production-line environments.<\/p>\n<h3>Key benefits<\/h3>\n<ul>\n<li>1\u20136 blisters and up to 72 points per sequence<\/li>\n<li>Optical headspace measurement with no O\u2082 consumption<\/li>\n<li>Automatic calibration and dedicated blister cartridges<\/li>\n<li>Statistical reports and 21 CFR Part 11 software<\/li>\n<li>USB, RS485 and Ethernet interfaces<\/li>\n<\/ul>\n<h3>Applications<\/h3>\n<ul>\n<li>O\u2082 control in pharmaceutical blister packs<\/li>\n<li>Modified-atmosphere packaging validation<\/li>\n<li>Quality control and production integration<\/li>\n<li>Stability studies and packaging-process optimization<\/li>\n<\/ul>\n<h3>Technical specifications<\/h3>\n<table width=\"624\">\n<thead>\n<tr>\n<td width=\"180\"><strong>Parameter<\/strong><\/td>\n<td width=\"444\"><strong>Specification<\/strong><\/td>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td width=\"180\"><strong>O\u2082 range<\/strong><\/td>\n<td width=\"444\">0\u201325%<\/td>\n<\/tr>\n<tr>\n<td width=\"180\"><strong>Accuracy<\/strong><\/td>\n<td width=\"444\">\u00b10.1% O\u2082<\/td>\n<\/tr>\n<tr>\n<td width=\"180\"><strong>Detection limit<\/strong><\/td>\n<td width=\"444\">0.1% O\u2082<\/td>\n<\/tr>\n<tr>\n<td width=\"180\"><strong>Needles<\/strong><\/td>\n<td width=\"444\">0.4 \/ 0.8 mm<\/td>\n<\/tr>\n<tr>\n<td width=\"180\"><strong>Positioning<\/strong><\/td>\n<td width=\"444\">&lt;0.02 mm<\/td>\n<\/tr>\n<tr>\n<td width=\"180\"><strong>Operating temperature<\/strong><\/td>\n<td width=\"444\">18\u201325 \u00b0C<\/td>\n<\/tr>\n<tr>\n<td width=\"180\"><strong>Interfaces<\/strong><\/td>\n<td width=\"444\">USB, RS485, Ethernet<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p><em>Confirm the final configuration, available options and current specification version in the quotation.<\/em><\/p>\n<h3>Frequently asked questions<\/h3>\n<p><strong>Does measurement consume oxygen?<\/strong><\/p>\n<p>No. The optical principle does not consume O\u2082 during analysis.<\/p>\n<p><strong>Can it analyse several blisters?<\/strong><\/p>\n<p>Yes. It can analyse 1\u20136 blisters and up to 72 points in a sequence.<\/p>\n<p><strong>Is it suitable for GMP environments?<\/strong><\/p>\n<p>It provides 21 CFR Part 11 functions and IQ\/OQ documentation; integration into the quality system must be validated by the user.<\/p>\n<h3><\/h3>\n<p>Send APEL Laser your sample type, applicable method, required capacity and desired parameters. We will recommend the suitable ECHO configuration, accessories and implementation plan.<\/p>\n<p><strong>sales@apellaser.ro | Subject: ECHO Instruments enquiry<\/strong><\/p>\n","protected":false},"excerpt":{"rendered":"<p class=\"Callout\"><span lang=\"EN-US\">ECHO B-O2 is a fully automatic optical analyser for oxygen concentration in blister packs and other pharmaceutical modified-atmosphere packaging.<\/span><\/p>\n","protected":false},"featured_media":28347,"template":"","meta":[],"product_brand":[],"product_cat":[2200,3569],"product_tag":[],"class_list":["post-28349","product","type-product","status-publish","has-post-thumbnail","product_cat-laboratory-equipment","product_cat-respirometers","first","instock","shipping-taxable","product-type-simple"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v28.1 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>ECHO B-O2 automatic blister oxygen analyser<\/title>\n<meta name=\"description\" content=\"ECHO B-O2 automatically measures oxygen in pharmaceutical blister headspace at up to 72 points with 21 CFR Part 11 software.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/apellaser.ro\/en\/product\/echo-b-o2-automatic-oxygen-analyser\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"ECHO B-O2 automatic blister oxygen analyser\" \/>\n<meta property=\"og:description\" content=\"ECHO B-O2 automatically measures oxygen in pharmaceutical blister headspace at up to 72 points with 21 CFR Part 11 software.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/apellaser.ro\/en\/product\/echo-b-o2-automatic-oxygen-analyser\/\" \/>\n<meta property=\"og:site_name\" content=\"APEL LASER\" \/>\n<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/apellaser\" \/>\n<meta property=\"article:modified_time\" content=\"2026-07-28T11:03:41+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/apellaser.ro\/wp-content\/uploads\/2026\/07\/B-O2_b.webp\" \/>\n\t<meta property=\"og:image:width\" content=\"1600\" \/>\n\t<meta property=\"og:image:height\" content=\"1068\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/webp\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data1\" content=\"2 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/apellaser.ro\\\/en\\\/product\\\/echo-b-o2-automatic-oxygen-analyser\\\/\",\"url\":\"https:\\\/\\\/apellaser.ro\\\/en\\\/product\\\/echo-b-o2-automatic-oxygen-analyser\\\/\",\"name\":\"ECHO B-O2 automatic blister oxygen analyser\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/apellaser.ro\\\/en\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/apellaser.ro\\\/en\\\/product\\\/echo-b-o2-automatic-oxygen-analyser\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/apellaser.ro\\\/en\\\/product\\\/echo-b-o2-automatic-oxygen-analyser\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/apellaser.ro\\\/wp-content\\\/uploads\\\/2026\\\/07\\\/B-O2_b.webp\",\"datePublished\":\"2026-07-28T11:02:05+00:00\",\"dateModified\":\"2026-07-28T11:03:41+00:00\",\"description\":\"ECHO B-O2 automatically measures oxygen in pharmaceutical blister headspace at up to 72 points with 21 CFR Part 11 software.\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/apellaser.ro\\\/en\\\/product\\\/echo-b-o2-automatic-oxygen-analyser\\\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/apellaser.ro\\\/en\\\/product\\\/echo-b-o2-automatic-oxygen-analyser\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/apellaser.ro\\\/en\\\/product\\\/echo-b-o2-automatic-oxygen-analyser\\\/#primaryimage\",\"url\":\"https:\\\/\\\/apellaser.ro\\\/wp-content\\\/uploads\\\/2026\\\/07\\\/B-O2_b.webp\",\"contentUrl\":\"https:\\\/\\\/apellaser.ro\\\/wp-content\\\/uploads\\\/2026\\\/07\\\/B-O2_b.webp\",\"width\":1600,\"height\":1068},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/apellaser.ro\\\/en\\\/product\\\/echo-b-o2-automatic-oxygen-analyser\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Prima pagin\u0103\",\"item\":\"https:\\\/\\\/apellaser.ro\\\/en\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Products\",\"item\":\"https:\\\/\\\/apellaser.ro\\\/en\\\/shop\\\/\"},{\"@type\":\"ListItem\",\"position\":3,\"name\":\"ECHO B-O2 automatic oxygen analyser\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/apellaser.ro\\\/en\\\/#website\",\"url\":\"https:\\\/\\\/apellaser.ro\\\/en\\\/\",\"name\":\"APEL LASER\",\"description\":\"Lasers and Scientific instruments\",\"publisher\":{\"@id\":\"https:\\\/\\\/apellaser.ro\\\/en\\\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/apellaser.ro\\\/en\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/apellaser.ro\\\/en\\\/#organization\",\"name\":\"ApelLaser\",\"url\":\"https:\\\/\\\/apellaser.ro\\\/en\\\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/apellaser.ro\\\/en\\\/#\\\/schema\\\/logo\\\/image\\\/\",\"url\":\"https:\\\/\\\/apellaser.ro\\\/wp-content\\\/uploads\\\/2023\\\/08\\\/logo-apel-laser.png\",\"contentUrl\":\"https:\\\/\\\/apellaser.ro\\\/wp-content\\\/uploads\\\/2023\\\/08\\\/logo-apel-laser.png\",\"width\":1000,\"height\":500,\"caption\":\"ApelLaser\"},\"image\":{\"@id\":\"https:\\\/\\\/apellaser.ro\\\/en\\\/#\\\/schema\\\/logo\\\/image\\\/\"},\"sameAs\":[\"https:\\\/\\\/www.facebook.com\\\/apellaser\",\"https:\\\/\\\/www.linkedin.com\\\/company\\\/apel-laser\\\/\",\"https:\\\/\\\/www.youtube.com\\\/@APELLASER-di2xf\"]}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"ECHO B-O2 automatic blister oxygen analyser","description":"ECHO B-O2 automatically measures oxygen in pharmaceutical blister headspace at up to 72 points with 21 CFR Part 11 software.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/apellaser.ro\/en\/product\/echo-b-o2-automatic-oxygen-analyser\/","og_locale":"en_US","og_type":"article","og_title":"ECHO B-O2 automatic blister oxygen analyser","og_description":"ECHO B-O2 automatically measures oxygen in pharmaceutical blister headspace at up to 72 points with 21 CFR Part 11 software.","og_url":"https:\/\/apellaser.ro\/en\/product\/echo-b-o2-automatic-oxygen-analyser\/","og_site_name":"APEL LASER","article_publisher":"https:\/\/www.facebook.com\/apellaser","article_modified_time":"2026-07-28T11:03:41+00:00","og_image":[{"width":1600,"height":1068,"url":"https:\/\/apellaser.ro\/wp-content\/uploads\/2026\/07\/B-O2_b.webp","type":"image\/webp"}],"twitter_card":"summary_large_image","twitter_misc":{"Est. reading time":"2 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/apellaser.ro\/en\/product\/echo-b-o2-automatic-oxygen-analyser\/","url":"https:\/\/apellaser.ro\/en\/product\/echo-b-o2-automatic-oxygen-analyser\/","name":"ECHO B-O2 automatic blister oxygen analyser","isPartOf":{"@id":"https:\/\/apellaser.ro\/en\/#website"},"primaryImageOfPage":{"@id":"https:\/\/apellaser.ro\/en\/product\/echo-b-o2-automatic-oxygen-analyser\/#primaryimage"},"image":{"@id":"https:\/\/apellaser.ro\/en\/product\/echo-b-o2-automatic-oxygen-analyser\/#primaryimage"},"thumbnailUrl":"https:\/\/apellaser.ro\/wp-content\/uploads\/2026\/07\/B-O2_b.webp","datePublished":"2026-07-28T11:02:05+00:00","dateModified":"2026-07-28T11:03:41+00:00","description":"ECHO B-O2 automatically measures oxygen in pharmaceutical blister headspace at up to 72 points with 21 CFR Part 11 software.","breadcrumb":{"@id":"https:\/\/apellaser.ro\/en\/product\/echo-b-o2-automatic-oxygen-analyser\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/apellaser.ro\/en\/product\/echo-b-o2-automatic-oxygen-analyser\/"]}]},{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/apellaser.ro\/en\/product\/echo-b-o2-automatic-oxygen-analyser\/#primaryimage","url":"https:\/\/apellaser.ro\/wp-content\/uploads\/2026\/07\/B-O2_b.webp","contentUrl":"https:\/\/apellaser.ro\/wp-content\/uploads\/2026\/07\/B-O2_b.webp","width":1600,"height":1068},{"@type":"BreadcrumbList","@id":"https:\/\/apellaser.ro\/en\/product\/echo-b-o2-automatic-oxygen-analyser\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Prima pagin\u0103","item":"https:\/\/apellaser.ro\/en\/"},{"@type":"ListItem","position":2,"name":"Products","item":"https:\/\/apellaser.ro\/en\/shop\/"},{"@type":"ListItem","position":3,"name":"ECHO B-O2 automatic oxygen analyser"}]},{"@type":"WebSite","@id":"https:\/\/apellaser.ro\/en\/#website","url":"https:\/\/apellaser.ro\/en\/","name":"APEL LASER","description":"Lasers and Scientific instruments","publisher":{"@id":"https:\/\/apellaser.ro\/en\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/apellaser.ro\/en\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"},{"@type":"Organization","@id":"https:\/\/apellaser.ro\/en\/#organization","name":"ApelLaser","url":"https:\/\/apellaser.ro\/en\/","logo":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/apellaser.ro\/en\/#\/schema\/logo\/image\/","url":"https:\/\/apellaser.ro\/wp-content\/uploads\/2023\/08\/logo-apel-laser.png","contentUrl":"https:\/\/apellaser.ro\/wp-content\/uploads\/2023\/08\/logo-apel-laser.png","width":1000,"height":500,"caption":"ApelLaser"},"image":{"@id":"https:\/\/apellaser.ro\/en\/#\/schema\/logo\/image\/"},"sameAs":["https:\/\/www.facebook.com\/apellaser","https:\/\/www.linkedin.com\/company\/apel-laser\/","https:\/\/www.youtube.com\/@APELLASER-di2xf"]}]}},"_links":{"self":[{"href":"https:\/\/apellaser.ro\/en\/wp-json\/wp\/v2\/product\/28349","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/apellaser.ro\/en\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/apellaser.ro\/en\/wp-json\/wp\/v2\/types\/product"}],"version-history":[{"count":1,"href":"https:\/\/apellaser.ro\/en\/wp-json\/wp\/v2\/product\/28349\/revisions"}],"predecessor-version":[{"id":28350,"href":"https:\/\/apellaser.ro\/en\/wp-json\/wp\/v2\/product\/28349\/revisions\/28350"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/apellaser.ro\/en\/wp-json\/wp\/v2\/media\/28347"}],"wp:attachment":[{"href":"https:\/\/apellaser.ro\/en\/wp-json\/wp\/v2\/media?parent=28349"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/apellaser.ro\/en\/wp-json\/wp\/v2\/product_brand?post=28349"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/apellaser.ro\/en\/wp-json\/wp\/v2\/product_cat?post=28349"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/apellaser.ro\/en\/wp-json\/wp\/v2\/product_tag?post=28349"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}