{"id":28129,"date":"2026-07-24T19:17:57","date_gmt":"2026-07-24T16:17:57","guid":{"rendered":"https:\/\/apellaser.ro\/?post_type=product&#038;p=28129"},"modified":"2026-07-24T19:22:26","modified_gmt":"2026-07-24T16:22:26","slug":"partica-laser-diffraction-and-dynamic-imaging-particle-size-and-shape-analyzer-horiba","status":"publish","type":"product","link":"https:\/\/apellaser.ro\/en\/product\/partica-laser-diffraction-and-dynamic-imaging-particle-size-and-shape-analyzer-horiba\/","title":{"rendered":"Partica Laser Diffraction and Dynamic Imaging Particle Size and Shape Analyzer | HORIBA"},"content":{"rendered":"<p>Particle size and shape influence powder flow, suspension stability, reactivity, product appearance and process performance. Partica brings two complementary techniques into one platform: laser diffraction rapidly measures a very broad size distribution, while dynamic imaging reveals outliers, agglomerates and individual-particle morphology. Correlated results support more confident decisions in research, method development and quality control.<\/p>\n<h2>Main benefits<\/h2>\n<p><strong>Two perspectives in one analysis. <\/strong>Combines volume-based particle-size distribution from LD with particle images and morphology information from DIA.<\/p>\n<p><strong>Extended dynamic range. <\/strong>The LA-1000 configuration covers a total range of 0.01-8000 \u00b5m, depending on technique, dispersion mode and particle shape.<\/p>\n<p><strong>Fast, representative analysis. <\/strong>The dual-camera system captures up to 300 frames\/s, enabling tens of thousands of particles to be assessed in a short time.<\/p>\n<p><strong>Designed for real samples. <\/strong>Accessories for wet dispersion, powders, small volumes, concentrated suspensions and pastes extend the platform across varied R&amp;D and QC workflows.<\/p>\n<p><strong>Repeatability and traceability. <\/strong>Automatic optical alignment, NIST-traceable standard verification and the software architecture support robust, transferable methods.<\/p>\n<p><strong>Laboratory productivity. <\/strong>One platform reduces instrument changes, total measurement time and occupied laboratory space.<\/p>\n<h2>Key features<\/h2>\n<ul>\n<li>2-in-1 laser diffraction\/scattering and dynamic image analysis in the LA-1000 configuration.<\/li>\n<li>Dual-camera DIA system with different magnifications, covering particles from approximately 1 \u00b5m to several millimetres.<\/li>\n<li>Minimum digital resolution of 0.3 \u00b5m and maximum acquisition rate of 300 frames\/s.<\/li>\n<li>More than 30 image-analysis parameters, including equivalent diameter, minimum\/maximum Feret diameter, circularity and aspect ratio.<\/li>\n<li>Dual optical sources for LD: 650 nm red laser diode and 405 nm violet LED.<\/li>\n<li>LD accuracy within \u00b10.6% of certified reference particle standards, based on HORIBA verification.<\/li>\n<li>Measurement of liquids, slurries, powders and high-solids samples.<\/li>\n<li>Rapid changeover between measurement cells and dispersion modes.<\/li>\n<li>Intuitive software and PLATINALINK data-integrity features.<\/li>\n<li>Software features supporting FDA 21 CFR Part 11 and methods aligned with ISO 13320:2020 and ISO 13322-2:2021.<\/li>\n<\/ul>\n<h1>How the two techniques work<\/h1>\n<p><strong>Laser diffraction (LD). <\/strong>Determines particle-size distribution by analysing scattered light using Mie and Fraunhofer models. It is fast and covers particles from tens of nanometres to millimetres.<\/p>\n<p><strong>Dynamic image analysis (DIA). <\/strong>Records particles in motion and measures individual size and shape. It is valuable for identifying agglomerates, fibres, elongated particles and rare contaminants.<\/p>\n<p><strong>Combined interpretation. <\/strong>LD provides the global distribution, while DIA reveals which particle types produce the observed fractions. Correlation is valuable when a size distribution alone does not explain sample behaviour.<\/p>\n<h1>Available configurations<\/h1>\n<table width=\"624\">\n<thead>\n<tr>\n<td width=\"120\"><strong>Configuration<\/strong><\/td>\n<td width=\"167\"><strong>Techniques<\/strong><\/td>\n<td width=\"120\"><strong>Total range<\/strong><\/td>\n<td width=\"217\"><strong>Positioning<\/strong><\/td>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td width=\"120\">LA-1000 series<\/td>\n<td width=\"167\">LD + dual-camera DIA<\/td>\n<td width=\"120\">0.01-8000 \u00b5m<\/td>\n<td width=\"217\">Simultaneous size and shape characterization<\/td>\n<\/tr>\n<tr>\n<td width=\"120\">LA-970 series<\/td>\n<td width=\"167\">Laser diffraction<\/td>\n<td width=\"120\">0.01-5000 \u00b5m<\/td>\n<td width=\"217\">Particle-size distribution by LD<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>&nbsp;<\/p>\n<h1>Applications<\/h1>\n<p><strong>Batteries and energy materials. <\/strong>Electrode active materials, graphite, LFP\/NMC, electrode slurries and detection of agglomerates at process-relevant concentrations.<\/p>\n<p><strong>Pharmaceuticals and biotechnology. <\/strong>Powders, excipients, APIs and suspensions, with options addressing data integrity and electronic records.<\/p>\n<p><strong>Food and beverage. <\/strong>Food powders, starches, ingredients, emulsions and water-soluble particulate materials.<\/p>\n<p><strong>Paints, inks and pigments. <\/strong>Size distribution, oversized particles, agglomeration state and measurement with little or no dilution.<\/p>\n<p><strong>Ceramics, cement and minerals. <\/strong>Broad powder distributions, irregular granules and raw-material consistency control.<\/p>\n<p><strong>Polymers and composites. <\/strong>Microparticles, fillers, fibres and particles dispersed in viscous media.<\/p>\n<p><strong>Chemicals and advanced materials. <\/strong>Silica, catalysts, reference particles, CMP slurries and materials with complex morphology.<\/p>\n<p><strong>Contaminant and agglomerate control. <\/strong>Detection of rare or oversized particles that can be masked within a global volume-based distribution.<\/p>\n<h1>Technical specifications<\/h1>\n<table width=\"624\">\n<tbody>\n<tr>\n<td width=\"180\"><strong>Measurement principles<\/strong><\/td>\n<td width=\"444\">LD: Mie scattering and Fraunhofer diffraction; DIA: dynamic image analysis on LA-1000<\/td>\n<\/tr>\n<tr>\n<td width=\"180\"><strong>Total range &#8211; LA-1000<\/strong><\/td>\n<td width=\"444\">0.01-8000 \u00b5m<\/td>\n<\/tr>\n<tr>\n<td width=\"180\"><strong>Total range &#8211; LA-970<\/strong><\/td>\n<td width=\"444\">0.01-5000 \u00b5m<\/td>\n<\/tr>\n<tr>\n<td width=\"180\"><strong>LD &#8211; wet dispersion<\/strong><\/td>\n<td width=\"444\">0.01-3000 \u00b5m<\/td>\n<\/tr>\n<tr>\n<td width=\"180\"><strong>DIA &#8211; wet dispersion<\/strong><\/td>\n<td width=\"444\">0.3-3000 \u00b5m; dependent on particle shape<\/td>\n<\/tr>\n<tr>\n<td width=\"180\"><strong>LD &#8211; dry dispersion<\/strong><\/td>\n<td width=\"444\">0.1-5000 \u00b5m<\/td>\n<\/tr>\n<tr>\n<td width=\"180\"><strong>DIA &#8211; dry dispersion<\/strong><\/td>\n<td width=\"444\">1.1-8000 \u00b5m; dependent on particle shape<\/td>\n<\/tr>\n<tr>\n<td width=\"180\"><strong>LD light sources<\/strong><\/td>\n<td width=\"444\">650 nm laser diode, 5 mW; 405 nm LED, maximum 10 mW<\/td>\n<\/tr>\n<tr>\n<td width=\"180\"><strong>DIA cameras<\/strong><\/td>\n<td width=\"444\">2 cameras; CMOS; up to 300 frames\/s; minimum digital resolution 0.3 \u00b5m<\/td>\n<\/tr>\n<tr>\n<td width=\"180\"><strong>DIA parameters<\/strong><\/td>\n<td width=\"444\">More than 30 image-analysis parameters<\/td>\n<\/tr>\n<tr>\n<td width=\"180\"><strong>Wet dispersion system<\/strong><\/td>\n<td width=\"444\">30 W, 20 kHz ultrasonic probe; 5 fill levels; 15 circulation speeds; maximum flow approx. 10 L\/min; capacity approx. 150 mL or more<\/td>\n<\/tr>\n<tr>\n<td width=\"180\"><strong>Dimensions<\/strong><\/td>\n<td width=\"444\">720 mm (W) \u00d7 565 mm (D) \u00d7 470 mm (H), excluding pipework, protrusions and accessories<\/td>\n<\/tr>\n<tr>\n<td width=\"180\"><strong>Weight<\/strong><\/td>\n<td width=\"444\">Approximately 56 kg<\/td>\n<\/tr>\n<tr>\n<td width=\"180\"><strong>Power<\/strong><\/td>\n<td width=\"444\">AC 100-240 V, 50\/60 Hz, 300 VA<\/td>\n<\/tr>\n<tr>\n<td width=\"180\"><strong>PC interface<\/strong><\/td>\n<td width=\"444\">1 \u00d7 USB 3.1, 5 Gbps or faster<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p><em>Specifications vary by configuration and are subject to manufacturer change. Confirm the final configuration in the quotation.<\/em><\/p>\n<h1>Accessories and sampling options<\/h1>\n<p><strong>Wet circulation system. <\/strong>Automated filling, circulation, ultrasonication and rinsing; measurement and result display can be completed in approximately 60 s, depending on the method.<\/p>\n<p><strong>Powderjet Dry Powder Feeder. <\/strong>Powder analysis by free fall or forced dispersion with compressed air; accessories support adhesive, magnetic, poorly flowing or limited-quantity powders.<\/p>\n<p><strong>MiniFlow. <\/strong>Automated small-volume circulation for organic solvents; approximately 35 mL dispersant requirement and integrated ultrasonic probe.<\/p>\n<p><strong>Fraction Cell. <\/strong>5, 10 or 15 mL cells for rare samples, volatile solvents or full sample recovery; LD range 0.01-1000 \u00b5m.<\/p>\n<p><strong>High Concentration Cell. <\/strong>Measures inks, paints, pigments, emulsions and battery slurries with little or no dilution.<\/p>\n<p><strong>Paste Cell. <\/strong>For undiluted samples or particles in viscous media, including polymers and magnetic powders.<\/p>\n<h1>Configure Partica for your samples and method<\/h1>\n<table width=\"624\">\n<tbody>\n<tr>\n<td width=\"624\"><strong>The appropriate configuration depends on size range, concentration, dispersion medium, particle shape and data-integrity requirements. Send the APEL Laser team a description of your sample, estimated range, solvent or powder state and analytical objective. We can recommend the suitable model, cells and accessories and discuss the feasibility of a demonstration measurement.<\/strong><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>&nbsp;<\/p>\n<p><strong><a href=\"mailto:sales@apellaser.ro?subject=HORIBA%20Partica%20Request\">Request a Partica configuration<\/a><\/strong><\/p>\n<h1>Frequently asked questions<\/h1>\n<p><strong>What does HORIBA Partica measure?<\/strong><\/p>\n<p>In the LA-1000 configuration, Partica measures size distribution by laser diffraction and individual particle size, shape and images by DIA. LA-970 is the laser-diffraction configuration.<\/p>\n<p><strong>What is the measurement range?<\/strong><\/p>\n<p>The total range reaches 0.01-8000 \u00b5m for LA-1000 and 0.01-5000 \u00b5m for LA-970. The effective range depends on technique, wet\/dry dispersion and particle shape.<\/p>\n<p><strong>Can it analyse both liquids and powders?<\/strong><\/p>\n<p>Yes. The system accepts liquids and slurries, while the Powderjet accessory supports free-fall or compressed-air dispersion of powders.<\/p>\n<p><strong>Why combine LD and DIA?<\/strong><\/p>\n<p>LD rapidly provides the global size distribution, while DIA shows morphology and individual particles. Together they help distinguish primary particles from agglomerates and reveal rare contaminants.<\/p>\n<p><strong>Can it measure concentrated slurries or pastes?<\/strong><\/p>\n<p>Yes, using the optional High Concentration Cell and Paste Cell, subject to sample compatibility and method limits.<\/p>\n<p><strong>Is it suitable for regulated environments?<\/strong><\/p>\n<p>The software includes data-integrity functions and features supporting FDA 21 CFR Part 11. Method and system validation remain the responsibility of the user laboratory.<\/p>\n<p><strong>How does it differ from Partica LA-960V2?<\/strong><\/p>\n<p>LA-960V2 is an established laser-diffraction analyser. The new Partica LA-1000 platform adds dynamic image analysis and two cameras for simultaneous size and shape characterization.<\/p>\n","protected":false},"excerpt":{"rendered":"<p><strong>Partica<\/strong> is HORIBA&#8217;s comprehensive particle-characterization platform combining laser diffraction (LD) with dynamic image analysis (DIA). In the LA-1000 configuration, it simultaneously determines particle-size distribution and shape parameters for liquids, concentrated suspensions and powders, reducing analysis time and laboratory footprint.<\/p>\n","protected":false},"featured_media":28123,"template":"","meta":[],"product_brand":[],"product_cat":[2365,2843],"product_tag":[],"class_list":["post-28129","product","type-product","status-publish","has-post-thumbnail","product_cat-analytical-instruments","product_cat-laser-granulometric-analyzer","first","instock","shipping-taxable","product-type-simple"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v28.1 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>Partica HORIBA Particle Size and Shape Analyzer<\/title>\n<meta name=\"description\" content=\"HORIBA Partica combines laser diffraction and dynamic imaging for simultaneous particle size and shape analysis across a total range of 0.01-8000 \u00b5m.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/apellaser.ro\/en\/product\/partica-laser-diffraction-and-dynamic-imaging-particle-size-and-shape-analyzer-horiba\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Partica HORIBA Particle Size and Shape Analyzer\" \/>\n<meta property=\"og:description\" content=\"HORIBA Partica combines laser diffraction and dynamic imaging for simultaneous particle size and shape analysis across a total range of 0.01-8000 \u00b5m.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/apellaser.ro\/en\/product\/partica-laser-diffraction-and-dynamic-imaging-particle-size-and-shape-analyzer-horiba\/\" \/>\n<meta property=\"og:site_name\" content=\"APEL LASER\" \/>\n<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/apellaser\" \/>\n<meta property=\"article:modified_time\" content=\"2026-07-24T16:22:26+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/apellaser.ro\/wp-content\/uploads\/2026\/07\/csm_Partica_front_R3_8642f69e37.webp\" \/>\n\t<meta property=\"og:image:width\" content=\"1200\" \/>\n\t<meta property=\"og:image:height\" content=\"960\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/webp\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data1\" content=\"7 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/apellaser.ro\\\/en\\\/product\\\/partica-laser-diffraction-and-dynamic-imaging-particle-size-and-shape-analyzer-horiba\\\/\",\"url\":\"https:\\\/\\\/apellaser.ro\\\/en\\\/product\\\/partica-laser-diffraction-and-dynamic-imaging-particle-size-and-shape-analyzer-horiba\\\/\",\"name\":\"Partica HORIBA Particle Size and Shape Analyzer\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/apellaser.ro\\\/en\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/apellaser.ro\\\/en\\\/product\\\/partica-laser-diffraction-and-dynamic-imaging-particle-size-and-shape-analyzer-horiba\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/apellaser.ro\\\/en\\\/product\\\/partica-laser-diffraction-and-dynamic-imaging-particle-size-and-shape-analyzer-horiba\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/apellaser.ro\\\/wp-content\\\/uploads\\\/2026\\\/07\\\/csm_Partica_front_R3_8642f69e37.webp\",\"datePublished\":\"2026-07-24T16:17:57+00:00\",\"dateModified\":\"2026-07-24T16:22:26+00:00\",\"description\":\"HORIBA Partica combines laser diffraction and dynamic imaging for simultaneous particle size and shape analysis across a total range of 0.01-8000 \u00b5m.\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/apellaser.ro\\\/en\\\/product\\\/partica-laser-diffraction-and-dynamic-imaging-particle-size-and-shape-analyzer-horiba\\\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/apellaser.ro\\\/en\\\/product\\\/partica-laser-diffraction-and-dynamic-imaging-particle-size-and-shape-analyzer-horiba\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/apellaser.ro\\\/en\\\/product\\\/partica-laser-diffraction-and-dynamic-imaging-particle-size-and-shape-analyzer-horiba\\\/#primaryimage\",\"url\":\"https:\\\/\\\/apellaser.ro\\\/wp-content\\\/uploads\\\/2026\\\/07\\\/csm_Partica_front_R3_8642f69e37.webp\",\"contentUrl\":\"https:\\\/\\\/apellaser.ro\\\/wp-content\\\/uploads\\\/2026\\\/07\\\/csm_Partica_front_R3_8642f69e37.webp\",\"width\":1200,\"height\":960},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/apellaser.ro\\\/en\\\/product\\\/partica-laser-diffraction-and-dynamic-imaging-particle-size-and-shape-analyzer-horiba\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Prima pagin\u0103\",\"item\":\"https:\\\/\\\/apellaser.ro\\\/en\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Products\",\"item\":\"https:\\\/\\\/apellaser.ro\\\/en\\\/shop\\\/\"},{\"@type\":\"ListItem\",\"position\":3,\"name\":\"Partica Laser Diffraction and Dynamic Imaging Particle Size and Shape Analyzer | HORIBA\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/apellaser.ro\\\/en\\\/#website\",\"url\":\"https:\\\/\\\/apellaser.ro\\\/en\\\/\",\"name\":\"APEL LASER\",\"description\":\"INOVATIE SI PERFORMANTA DE 20 DE ANI\",\"publisher\":{\"@id\":\"https:\\\/\\\/apellaser.ro\\\/en\\\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/apellaser.ro\\\/en\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/apellaser.ro\\\/en\\\/#organization\",\"name\":\"ApelLaser\",\"url\":\"https:\\\/\\\/apellaser.ro\\\/en\\\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/apellaser.ro\\\/en\\\/#\\\/schema\\\/logo\\\/image\\\/\",\"url\":\"https:\\\/\\\/apellaser.ro\\\/wp-content\\\/uploads\\\/2023\\\/08\\\/logo-apel-laser.png\",\"contentUrl\":\"https:\\\/\\\/apellaser.ro\\\/wp-content\\\/uploads\\\/2023\\\/08\\\/logo-apel-laser.png\",\"width\":1000,\"height\":500,\"caption\":\"ApelLaser\"},\"image\":{\"@id\":\"https:\\\/\\\/apellaser.ro\\\/en\\\/#\\\/schema\\\/logo\\\/image\\\/\"},\"sameAs\":[\"https:\\\/\\\/www.facebook.com\\\/apellaser\",\"https:\\\/\\\/www.linkedin.com\\\/company\\\/apel-laser\\\/\",\"https:\\\/\\\/www.youtube.com\\\/@APELLASER-di2xf\"]}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Partica HORIBA Particle Size and Shape Analyzer","description":"HORIBA Partica combines laser diffraction and dynamic imaging for simultaneous particle size and shape analysis across a total range of 0.01-8000 \u00b5m.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/apellaser.ro\/en\/product\/partica-laser-diffraction-and-dynamic-imaging-particle-size-and-shape-analyzer-horiba\/","og_locale":"en_US","og_type":"article","og_title":"Partica HORIBA Particle Size and Shape Analyzer","og_description":"HORIBA Partica combines laser diffraction and dynamic imaging for simultaneous particle size and shape analysis across a total range of 0.01-8000 \u00b5m.","og_url":"https:\/\/apellaser.ro\/en\/product\/partica-laser-diffraction-and-dynamic-imaging-particle-size-and-shape-analyzer-horiba\/","og_site_name":"APEL LASER","article_publisher":"https:\/\/www.facebook.com\/apellaser","article_modified_time":"2026-07-24T16:22:26+00:00","og_image":[{"width":1200,"height":960,"url":"https:\/\/apellaser.ro\/wp-content\/uploads\/2026\/07\/csm_Partica_front_R3_8642f69e37.webp","type":"image\/webp"}],"twitter_card":"summary_large_image","twitter_misc":{"Est. reading time":"7 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/apellaser.ro\/en\/product\/partica-laser-diffraction-and-dynamic-imaging-particle-size-and-shape-analyzer-horiba\/","url":"https:\/\/apellaser.ro\/en\/product\/partica-laser-diffraction-and-dynamic-imaging-particle-size-and-shape-analyzer-horiba\/","name":"Partica HORIBA Particle Size and Shape Analyzer","isPartOf":{"@id":"https:\/\/apellaser.ro\/en\/#website"},"primaryImageOfPage":{"@id":"https:\/\/apellaser.ro\/en\/product\/partica-laser-diffraction-and-dynamic-imaging-particle-size-and-shape-analyzer-horiba\/#primaryimage"},"image":{"@id":"https:\/\/apellaser.ro\/en\/product\/partica-laser-diffraction-and-dynamic-imaging-particle-size-and-shape-analyzer-horiba\/#primaryimage"},"thumbnailUrl":"https:\/\/apellaser.ro\/wp-content\/uploads\/2026\/07\/csm_Partica_front_R3_8642f69e37.webp","datePublished":"2026-07-24T16:17:57+00:00","dateModified":"2026-07-24T16:22:26+00:00","description":"HORIBA Partica combines laser diffraction and dynamic imaging for simultaneous particle size and shape analysis across a total range of 0.01-8000 \u00b5m.","breadcrumb":{"@id":"https:\/\/apellaser.ro\/en\/product\/partica-laser-diffraction-and-dynamic-imaging-particle-size-and-shape-analyzer-horiba\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/apellaser.ro\/en\/product\/partica-laser-diffraction-and-dynamic-imaging-particle-size-and-shape-analyzer-horiba\/"]}]},{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/apellaser.ro\/en\/product\/partica-laser-diffraction-and-dynamic-imaging-particle-size-and-shape-analyzer-horiba\/#primaryimage","url":"https:\/\/apellaser.ro\/wp-content\/uploads\/2026\/07\/csm_Partica_front_R3_8642f69e37.webp","contentUrl":"https:\/\/apellaser.ro\/wp-content\/uploads\/2026\/07\/csm_Partica_front_R3_8642f69e37.webp","width":1200,"height":960},{"@type":"BreadcrumbList","@id":"https:\/\/apellaser.ro\/en\/product\/partica-laser-diffraction-and-dynamic-imaging-particle-size-and-shape-analyzer-horiba\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Prima pagin\u0103","item":"https:\/\/apellaser.ro\/en\/"},{"@type":"ListItem","position":2,"name":"Products","item":"https:\/\/apellaser.ro\/en\/shop\/"},{"@type":"ListItem","position":3,"name":"Partica Laser Diffraction and Dynamic Imaging Particle Size and Shape Analyzer | HORIBA"}]},{"@type":"WebSite","@id":"https:\/\/apellaser.ro\/en\/#website","url":"https:\/\/apellaser.ro\/en\/","name":"APEL LASER","description":"INOVATIE SI PERFORMANTA DE 20 DE ANI","publisher":{"@id":"https:\/\/apellaser.ro\/en\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/apellaser.ro\/en\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"},{"@type":"Organization","@id":"https:\/\/apellaser.ro\/en\/#organization","name":"ApelLaser","url":"https:\/\/apellaser.ro\/en\/","logo":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/apellaser.ro\/en\/#\/schema\/logo\/image\/","url":"https:\/\/apellaser.ro\/wp-content\/uploads\/2023\/08\/logo-apel-laser.png","contentUrl":"https:\/\/apellaser.ro\/wp-content\/uploads\/2023\/08\/logo-apel-laser.png","width":1000,"height":500,"caption":"ApelLaser"},"image":{"@id":"https:\/\/apellaser.ro\/en\/#\/schema\/logo\/image\/"},"sameAs":["https:\/\/www.facebook.com\/apellaser","https:\/\/www.linkedin.com\/company\/apel-laser\/","https:\/\/www.youtube.com\/@APELLASER-di2xf"]}]}},"_links":{"self":[{"href":"https:\/\/apellaser.ro\/en\/wp-json\/wp\/v2\/product\/28129","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/apellaser.ro\/en\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/apellaser.ro\/en\/wp-json\/wp\/v2\/types\/product"}],"version-history":[{"count":1,"href":"https:\/\/apellaser.ro\/en\/wp-json\/wp\/v2\/product\/28129\/revisions"}],"predecessor-version":[{"id":28130,"href":"https:\/\/apellaser.ro\/en\/wp-json\/wp\/v2\/product\/28129\/revisions\/28130"}],"wp:attachment":[{"href":"https:\/\/apellaser.ro\/en\/wp-json\/wp\/v2\/media?parent=28129"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/apellaser.ro\/en\/wp-json\/wp\/v2\/product_brand?post=28129"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/apellaser.ro\/en\/wp-json\/wp\/v2\/product_cat?post=28129"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/apellaser.ro\/en\/wp-json\/wp\/v2\/product_tag?post=28129"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}