{"id":21743,"date":"2023-07-23T18:23:25","date_gmt":"2023-07-23T15:23:25","guid":{"rendered":"https:\/\/apellaser.ro\/product\/brochure-emga-930-oxygen-nitrogen-hydrogen-analyzer\/"},"modified":"2023-11-22T11:37:41","modified_gmt":"2023-11-22T09:37:41","slug":"brochure-emga-930-oxygen-nitrogen-hydrogen-analyzer","status":"publish","type":"product","link":"https:\/\/apellaser.ro\/en\/product\/brochure-emga-930-oxygen-nitrogen-hydrogen-analyzer\/","title":{"rendered":"EMGA-930 Oxygen-Nitrogen-Hydrogen Analyzer"},"content":{"rendered":"<p><strong>Features &amp; Benefits:<\/strong><\/p>\n<p>High performance: Wide range and high accuracy measurement.<br \/>\nUser friendly software: Simple software allows easy handling.<br \/>\nFully supported accessories give simple operation.<br \/>\nImproved mechanism.<br \/>\nDual sample\/flux introduction mechanism.<\/p>\n<p><strong>Technical Specifications:<\/strong><\/p>\n<p>Measurement range*:Oxygen: 0-5%, Nitrogen: 0-3%, Hydrogen: 0-0.25%<br \/>\n*Up to 100% wt is possible by decreasing the sample weight.<br \/>\nSample weight: 1.0 \u00b1 0.1g<br \/>\nSensitivity(Minimum reading): Oxygen\/Nitrogen\/Hydrogen: 0.001 ppm.<br \/>\nPower of furnace : Inert gas fusion in impulse furnace ,Enable to set the generating power 0 \u2013 8.0 kw.<br \/>\nAutomation functions: Auto cleaner, Crucible loader.<br \/>\nSample introduction: Dual sample\/flux introduction mechanism.<br \/>\nDimensions: 750mm(H)\u00d7785mm(D)\u00d7653mm(W) , Sample introduction is positioned at 650mm from table.<br \/>\nWeight: 230kg , On carrying, it is divided in two units (Under 140kg\/unit).<br \/>\nPower:<br \/>\nMain unit: AC200\/220\/230\/240V \u00b1 10%<br \/>\nAuto cleaner: AC100V (Step-down transformer)<br \/>\nFrequency: 50\/60 \u00b1 1Hz<\/p>\n","protected":false},"excerpt":{"rendered":"<p>The HORIBA EMGA-930 is a simultaneous Oxygen\/Nitrogen\/Hydrogen Analyzer featuring high accuracy and repeatability suited to advanced R&#038;D as well as quality control. It determines the O\/N\/H contained in ferrous and non-ferrous metals, ceramics, new materials, electronic materials and other inorganic materials using the inert gas fusion method.<\/p>\n<p><strong>Resources:<\/strong><\/p>\n<p><a href=\"https:\/\/apellaser.ro\/brochure-emga-930-oxygen-nitrogen-hydrogen-analyzer-2\/\"><button class=\"buton-resurse\">Brochure<\/button><\/a><a href=\"https:\/\/www.horiba.com\/int\/products\/detail\/action\/show\/Product\/emga-930-1370\/\" target=\"_blank\" rel=\"noopener\"><button class=\"buton-resurse\">Manufacturer<\/button><\/a><\/p>\n","protected":false},"featured_media":19836,"template":"","meta":[],"product_brand":[],"product_cat":[2365,2824],"product_tag":[],"class_list":{"0":"post-21743","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_cat-analytical-instruments","7":"product_cat-elemental-analyzers","8":"pa_aplicatii-industrii-analytical-chemistry-in-the-chemical-industry","9":"pa_aplicatii-industrii-battery-industry","10":"pa_aplicatii-industrii-catalysis","11":"pa_aplicatii-industrii-nanotechnology","12":"pa_aplicatii-industrii-sample-preparation-and-sampling-methods-for-gas-analysis-in-steel","13":"pa_aplicatii-industrii-steel-industry","14":"pa_metoda-de-masurare-non-dispersive","15":"pa_producator-horiba-en","17":"first","18":"instock","19":"product-type-simple"},"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v27.3 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>EMGA-930 Oxygen-Nitrogen-Hydrogen Analyzer - APEL LASER<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/apellaser.ro\/en\/product\/brochure-emga-930-oxygen-nitrogen-hydrogen-analyzer\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"EMGA-930 Oxygen-Nitrogen-Hydrogen Analyzer - APEL LASER\" \/>\n<meta property=\"og:description\" content=\"The HORIBA EMGA-930 is a simultaneous Oxygen\/Nitrogen\/Hydrogen Analyzer featuring high accuracy and repeatability suited to advanced R&amp;D as well as quality control. It determines the O\/N\/H contained in ferrous and non-ferrous metals, ceramics, new materials, electronic materials and other inorganic materials using the inert gas fusion method.  Resources:  BrochureManufacturer\" \/>\n<meta property=\"og:url\" content=\"https:\/\/apellaser.ro\/en\/product\/brochure-emga-930-oxygen-nitrogen-hydrogen-analyzer\/\" \/>\n<meta property=\"og:site_name\" content=\"APEL LASER\" \/>\n<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/apellaser\" \/>\n<meta property=\"article:modified_time\" content=\"2023-11-22T09:37:41+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/apellaser.ro\/wp-content\/uploads\/2023\/07\/EMGA-930.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"1200\" \/>\n\t<meta property=\"og:image:height\" content=\"1200\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data1\" content=\"1 minute\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/apellaser.ro\\\/en\\\/product\\\/brochure-emga-930-oxygen-nitrogen-hydrogen-analyzer\\\/\",\"url\":\"https:\\\/\\\/apellaser.ro\\\/en\\\/product\\\/brochure-emga-930-oxygen-nitrogen-hydrogen-analyzer\\\/\",\"name\":\"EMGA-930 Oxygen-Nitrogen-Hydrogen Analyzer - APEL LASER\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/apellaser.ro\\\/en\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/apellaser.ro\\\/en\\\/product\\\/brochure-emga-930-oxygen-nitrogen-hydrogen-analyzer\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/apellaser.ro\\\/en\\\/product\\\/brochure-emga-930-oxygen-nitrogen-hydrogen-analyzer\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/apellaser.ro\\\/wp-content\\\/uploads\\\/2023\\\/07\\\/EMGA-930.jpg\",\"datePublished\":\"2023-07-23T15:23:25+00:00\",\"dateModified\":\"2023-11-22T09:37:41+00:00\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/apellaser.ro\\\/en\\\/product\\\/brochure-emga-930-oxygen-nitrogen-hydrogen-analyzer\\\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/apellaser.ro\\\/en\\\/product\\\/brochure-emga-930-oxygen-nitrogen-hydrogen-analyzer\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/apellaser.ro\\\/en\\\/product\\\/brochure-emga-930-oxygen-nitrogen-hydrogen-analyzer\\\/#primaryimage\",\"url\":\"https:\\\/\\\/apellaser.ro\\\/wp-content\\\/uploads\\\/2023\\\/07\\\/EMGA-930.jpg\",\"contentUrl\":\"https:\\\/\\\/apellaser.ro\\\/wp-content\\\/uploads\\\/2023\\\/07\\\/EMGA-930.jpg\",\"width\":1200,\"height\":1200,\"caption\":\"Analizor elementar\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/apellaser.ro\\\/en\\\/product\\\/brochure-emga-930-oxygen-nitrogen-hydrogen-analyzer\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Prima pagin\u0103\",\"item\":\"https:\\\/\\\/apellaser.ro\\\/en\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Products\",\"item\":\"https:\\\/\\\/apellaser.ro\\\/en\\\/shop\\\/\"},{\"@type\":\"ListItem\",\"position\":3,\"name\":\"EMGA-930 Oxygen-Nitrogen-Hydrogen Analyzer\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/apellaser.ro\\\/en\\\/#website\",\"url\":\"https:\\\/\\\/apellaser.ro\\\/en\\\/\",\"name\":\"APEL LASER\",\"description\":\"INOVATIE SI PERFORMANTA DE 20 DE ANI\",\"publisher\":{\"@id\":\"https:\\\/\\\/apellaser.ro\\\/en\\\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/apellaser.ro\\\/en\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/apellaser.ro\\\/en\\\/#organization\",\"name\":\"ApelLaser\",\"url\":\"https:\\\/\\\/apellaser.ro\\\/en\\\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/apellaser.ro\\\/en\\\/#\\\/schema\\\/logo\\\/image\\\/\",\"url\":\"https:\\\/\\\/apellaser.ro\\\/wp-content\\\/uploads\\\/2023\\\/08\\\/logo-apel-laser.png\",\"contentUrl\":\"https:\\\/\\\/apellaser.ro\\\/wp-content\\\/uploads\\\/2023\\\/08\\\/logo-apel-laser.png\",\"width\":1000,\"height\":500,\"caption\":\"ApelLaser\"},\"image\":{\"@id\":\"https:\\\/\\\/apellaser.ro\\\/en\\\/#\\\/schema\\\/logo\\\/image\\\/\"},\"sameAs\":[\"https:\\\/\\\/www.facebook.com\\\/apellaser\",\"https:\\\/\\\/www.linkedin.com\\\/company\\\/apel-laser\\\/\",\"https:\\\/\\\/www.youtube.com\\\/@APELLASER-di2xf\"]}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"EMGA-930 Oxygen-Nitrogen-Hydrogen Analyzer - APEL LASER","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/apellaser.ro\/en\/product\/brochure-emga-930-oxygen-nitrogen-hydrogen-analyzer\/","og_locale":"en_US","og_type":"article","og_title":"EMGA-930 Oxygen-Nitrogen-Hydrogen Analyzer - APEL LASER","og_description":"The HORIBA EMGA-930 is a simultaneous Oxygen\/Nitrogen\/Hydrogen Analyzer featuring high accuracy and repeatability suited to advanced R&D as well as quality control. It determines the O\/N\/H contained in ferrous and non-ferrous metals, ceramics, new materials, electronic materials and other inorganic materials using the inert gas fusion method.  Resources:  BrochureManufacturer","og_url":"https:\/\/apellaser.ro\/en\/product\/brochure-emga-930-oxygen-nitrogen-hydrogen-analyzer\/","og_site_name":"APEL LASER","article_publisher":"https:\/\/www.facebook.com\/apellaser","article_modified_time":"2023-11-22T09:37:41+00:00","og_image":[{"width":1200,"height":1200,"url":"https:\/\/apellaser.ro\/wp-content\/uploads\/2023\/07\/EMGA-930.jpg","type":"image\/jpeg"}],"twitter_card":"summary_large_image","twitter_misc":{"Est. reading time":"1 minute"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/apellaser.ro\/en\/product\/brochure-emga-930-oxygen-nitrogen-hydrogen-analyzer\/","url":"https:\/\/apellaser.ro\/en\/product\/brochure-emga-930-oxygen-nitrogen-hydrogen-analyzer\/","name":"EMGA-930 Oxygen-Nitrogen-Hydrogen Analyzer - APEL LASER","isPartOf":{"@id":"https:\/\/apellaser.ro\/en\/#website"},"primaryImageOfPage":{"@id":"https:\/\/apellaser.ro\/en\/product\/brochure-emga-930-oxygen-nitrogen-hydrogen-analyzer\/#primaryimage"},"image":{"@id":"https:\/\/apellaser.ro\/en\/product\/brochure-emga-930-oxygen-nitrogen-hydrogen-analyzer\/#primaryimage"},"thumbnailUrl":"https:\/\/apellaser.ro\/wp-content\/uploads\/2023\/07\/EMGA-930.jpg","datePublished":"2023-07-23T15:23:25+00:00","dateModified":"2023-11-22T09:37:41+00:00","breadcrumb":{"@id":"https:\/\/apellaser.ro\/en\/product\/brochure-emga-930-oxygen-nitrogen-hydrogen-analyzer\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/apellaser.ro\/en\/product\/brochure-emga-930-oxygen-nitrogen-hydrogen-analyzer\/"]}]},{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/apellaser.ro\/en\/product\/brochure-emga-930-oxygen-nitrogen-hydrogen-analyzer\/#primaryimage","url":"https:\/\/apellaser.ro\/wp-content\/uploads\/2023\/07\/EMGA-930.jpg","contentUrl":"https:\/\/apellaser.ro\/wp-content\/uploads\/2023\/07\/EMGA-930.jpg","width":1200,"height":1200,"caption":"Analizor elementar"},{"@type":"BreadcrumbList","@id":"https:\/\/apellaser.ro\/en\/product\/brochure-emga-930-oxygen-nitrogen-hydrogen-analyzer\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Prima pagin\u0103","item":"https:\/\/apellaser.ro\/en\/"},{"@type":"ListItem","position":2,"name":"Products","item":"https:\/\/apellaser.ro\/en\/shop\/"},{"@type":"ListItem","position":3,"name":"EMGA-930 Oxygen-Nitrogen-Hydrogen Analyzer"}]},{"@type":"WebSite","@id":"https:\/\/apellaser.ro\/en\/#website","url":"https:\/\/apellaser.ro\/en\/","name":"APEL LASER","description":"INOVATIE SI PERFORMANTA DE 20 DE ANI","publisher":{"@id":"https:\/\/apellaser.ro\/en\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/apellaser.ro\/en\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"},{"@type":"Organization","@id":"https:\/\/apellaser.ro\/en\/#organization","name":"ApelLaser","url":"https:\/\/apellaser.ro\/en\/","logo":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/apellaser.ro\/en\/#\/schema\/logo\/image\/","url":"https:\/\/apellaser.ro\/wp-content\/uploads\/2023\/08\/logo-apel-laser.png","contentUrl":"https:\/\/apellaser.ro\/wp-content\/uploads\/2023\/08\/logo-apel-laser.png","width":1000,"height":500,"caption":"ApelLaser"},"image":{"@id":"https:\/\/apellaser.ro\/en\/#\/schema\/logo\/image\/"},"sameAs":["https:\/\/www.facebook.com\/apellaser","https:\/\/www.linkedin.com\/company\/apel-laser\/","https:\/\/www.youtube.com\/@APELLASER-di2xf"]}]}},"_links":{"self":[{"href":"https:\/\/apellaser.ro\/en\/wp-json\/wp\/v2\/product\/21743","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/apellaser.ro\/en\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/apellaser.ro\/en\/wp-json\/wp\/v2\/types\/product"}],"version-history":[{"count":2,"href":"https:\/\/apellaser.ro\/en\/wp-json\/wp\/v2\/product\/21743\/revisions"}],"predecessor-version":[{"id":23252,"href":"https:\/\/apellaser.ro\/en\/wp-json\/wp\/v2\/product\/21743\/revisions\/23252"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/apellaser.ro\/en\/wp-json\/wp\/v2\/media\/19836"}],"wp:attachment":[{"href":"https:\/\/apellaser.ro\/en\/wp-json\/wp\/v2\/media?parent=21743"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/apellaser.ro\/en\/wp-json\/wp\/v2\/product_brand?post=21743"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/apellaser.ro\/en\/wp-json\/wp\/v2\/product_cat?post=21743"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/apellaser.ro\/en\/wp-json\/wp\/v2\/product_tag?post=21743"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}