{"id":20143,"date":"2023-07-23T18:24:33","date_gmt":"2023-07-23T15:24:33","guid":{"rendered":"https:\/\/apellaser.ro\/product\/istar-340t-intensified-ccd-camera-andor\/"},"modified":"2023-11-21T10:46:21","modified_gmt":"2023-11-21T08:46:21","slug":"istar-340t-intensified-ccd-camera-andor","status":"publish","type":"product","link":"https:\/\/apellaser.ro\/en\/product\/istar-340t-intensified-ccd-camera-andor\/","title":{"rendered":"iStar 340T Intensified CCD camera | Andor"},"content":{"rendered":"<p><span data-sheets-value=\"{&quot;1&quot;:2,&quot;2&quot;:&quot;Features &amp; Benefits:nnHigh-resolution sensors and image intensifiers - Sharpest images and spectrum definition, 100% fill factor for maximum signal collection efficiency.nTrue optical gating &lt; 2 ns - Billionth of a second time-resolution for accurate transient phenomena study.n5 MHz readout platform - Rapid frame and spectral rates for superior characterization of dynamic phenomena. Single readout amplifier for best image digitization uniformitynSuperfast readout options Crop &amp; Fast Kinetic mode - Fully customizable binning sequences for highest spectral and image rates. Greater than 6,667 spectra\/s continuous rates, up to 55,250 spectra\/s in burst mode.nHigh QE Gen 2 &amp; 3 image intensifiers - Superior photon capture, with peak QE up to 50% and spectral coverage from 120 to 1,100 nm.nLow jitter, on-board Digital Delay Generator (DDG\u2122) - Highest gating timing accuracy with lowest propagation delay. Software controlled 3x triggering outputs with 10 ps setup accuracy for complex experiment integration.n500 kHz sustained photocathode gating - Maximizes signal-to-noise ratio in high repetition rate laser-based applicationsnTE-cooling to -40\u00baC - Efficient minimization of CCD dark current and pixel blemishes.nPhotocathode EBI minimization - Dry gas purge interface for further efficient EBI reduction.nIntelligate\u2122 - M Intelligent and accurate MCP gating for better than 1:108 shuttering efficiency in the UV.nnTechnical Specifications:nn&lt; 2 ns true optical gate.nUp to 3,571 spectra\/s.nIntegrated triple output DDG.nPhotocathode peak QE up to 50% .nIntegrate-On-Chip gating up to 500 kHz -40oC TE cooling.nUSB2 interface.&quot;}\" data-sheets-userformat=\"{&quot;2&quot;:14781,&quot;3&quot;:{&quot;1&quot;:0,&quot;3&quot;:1},&quot;5&quot;:{&quot;1&quot;:[{&quot;1&quot;:2,&quot;2&quot;:0,&quot;5&quot;:{&quot;1&quot;:2,&quot;2&quot;:0}},{&quot;1&quot;:0,&quot;2&quot;:0,&quot;3&quot;:3},{&quot;1&quot;:1,&quot;2&quot;:0,&quot;4&quot;:1}]},&quot;6&quot;:{&quot;1&quot;:[{&quot;1&quot;:2,&quot;2&quot;:0,&quot;5&quot;:{&quot;1&quot;:2,&quot;2&quot;:0}},{&quot;1&quot;:0,&quot;2&quot;:0,&quot;3&quot;:3},{&quot;1&quot;:1,&quot;2&quot;:0,&quot;4&quot;:1}]},&quot;7&quot;:{&quot;1&quot;:[{&quot;1&quot;:2,&quot;2&quot;:0,&quot;5&quot;:{&quot;1&quot;:2,&quot;2&quot;:0}},{&quot;1&quot;:0,&quot;2&quot;:0,&quot;3&quot;:3},{&quot;1&quot;:1,&quot;2&quot;:0,&quot;4&quot;:1}]},&quot;8&quot;:{&quot;1&quot;:[{&quot;1&quot;:2,&quot;2&quot;:0,&quot;5&quot;:{&quot;1&quot;:2,&quot;2&quot;:0}},{&quot;1&quot;:0,&quot;2&quot;:0,&quot;3&quot;:3},{&quot;1&quot;:1,&quot;2&quot;:0,&quot;4&quot;:1}]},&quot;10&quot;:0,&quot;11&quot;:4,&quot;14&quot;:{&quot;1&quot;:2,&quot;2&quot;:0},&quot;15&quot;:&quot;Calibri&quot;,&quot;16&quot;:11}\" data-sheets-textstyleruns=\"{&quot;1&quot;:0,&quot;2&quot;:{&quot;2&quot;:{&quot;1&quot;:2,&quot;2&quot;:0},&quot;3&quot;:&quot;Calibri&quot;,&quot;4&quot;:11,&quot;5&quot;:1}}\uee10{&quot;1&quot;:22,&quot;2&quot;:{&quot;2&quot;:{&quot;1&quot;:2,&quot;2&quot;:0},&quot;3&quot;:&quot;Calibri&quot;,&quot;4&quot;:11}}\uee10{&quot;1&quot;:1423,&quot;2&quot;:{&quot;2&quot;:{&quot;1&quot;:2,&quot;2&quot;:0},&quot;3&quot;:&quot;Calibri&quot;,&quot;4&quot;:11,&quot;5&quot;:1}}\uee10{&quot;1&quot;:1450,&quot;2&quot;:{&quot;2&quot;:{&quot;1&quot;:2,&quot;2&quot;:0},&quot;3&quot;:&quot;Calibri&quot;,&quot;4&quot;:11}}\"><strong>Features &amp; Benefits:<\/strong><\/span><\/p>\n<p>High-resolution sensors and image intensifiers &#8211; Sharpest images and spectrum definition, 100% fill factor for maximum signal collection efficiency.<br \/>\nTrue optical gating &lt; 2 ns &#8211; Billionth of a second time-resolution for accurate transient phenomena study.<br \/>\n5 MHz readout platform &#8211; Rapid frame and spectral rates for superior characterization of dynamic phenomena. Single readout amplifier for best image digitization uniformity<br \/>\nSuperfast readout options Crop &amp; Fast Kinetic mode &#8211; Fully customizable binning sequences for highest spectral and image rates. Greater than 6,667 spectra\/s continuous rates, up to 55,250 spectra\/s in burst mode.<br \/>\nHigh QE Gen 2 &amp; 3 image intensifiers &#8211; Superior photon capture, with peak QE up to 50% and spectral coverage from 120 to 1,100 nm.<br \/>\nLow jitter, on-board Digital Delay Generator (DDG\u2122) &#8211; Highest gating timing accuracy with lowest propagation delay. Software controlled 3x triggering outputs with 10 ps setup accuracy for complex experiment integration.<br \/>\n500 kHz sustained photocathode gating &#8211; Maximizes signal-to-noise ratio in high repetition rate laser-based applications<br \/>\nTE-cooling to -40\u00baC &#8211; Efficient minimization of CCD dark current and pixel blemishes.<br \/>\nPhotocathode EBI minimization &#8211; Dry gas purge interface for further efficient EBI reduction.<br \/>\nIntelligate\u2122 &#8211; M Intelligent and accurate MCP gating for better than 1:108 shuttering efficiency in the UV.<\/p>\n<p><strong>Technical Specifications:<\/strong><\/p>\n<p>&lt; 2 ns true optical gate.<br \/>\nUp to 3,571 spectra\/s.<br \/>\nIntegrated triple output DDG.<br \/>\nPhotocathode peak QE up to 50% .<br \/>\nIntegrate-On-Chip gating up to 500 kHz -40oC TE cooling.<br \/>\nUSB2 interface.<\/p>\n","protected":false},"excerpt":{"rendered":"<p>Andor\u2019s iStar 340T Intensified CCD sensor series is designed to offer the ultimate integrated detection solution for high resolution, ns-scale time-resolved Spectroscopy. The high resolution 2048 x 512 array with 13.5 \u00b5m pixel size offers a 4:1 aspect ratio which is ideally suited for use with Andor\u2019s Shamrock Czerny-Turner spectrograph series and accessories.<\/p>\n<p><strong>Resources:<\/strong><\/p>\n<p><a href=\"https:\/\/apellaser.ro\/wp-content\/uploads\/2023\/11\/Brochure-iStar-340T-Intensified-CCD-camera.pdf\"><button class=\"buton-resurse\">Brochure<\/button><\/a><a href=\"https:\/\/andor.oxinst.com\/products\/intensified-camera-series\/\" target=\"_blank\" rel=\"noopener\"><button class=\"buton-resurse\">Manufacturer<\/button><\/a><\/p>\n","protected":false},"featured_media":19072,"template":"","meta":[],"product_brand":[],"product_cat":[2192,2191,2190],"product_tag":[],"class_list":{"0":"post-20143","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_cat-camera-intensifiers","7":"product_cat-ccd-cameras","8":"product_cat-scientific-cameras","9":"pa_aplicatii-industrii-fluorescence","10":"pa_aplicatii-industrii-libsvuv-spectroscopy","11":"pa_aplicatii-industrii-photoluminescence","12":"pa_aplicatii-industrii-plasma-studies","13":"pa_aplicatii-industrii-raman-en","14":"pa_aplicatii-industrii-spectroscopy","15":"pa_aplicatii-industrii-spectroscopy-en","16":"pa_aplicatii-industrii-transient-absorption","17":"pa_dimensiunea-pixelilor-13-5-m-en","18":"pa_producator-oxford-instruments-en","20":"first","21":"instock","22":"product-type-simple"},"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v27.3 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>iStar 340T Intensified CCD camera | Andor - APEL LASER<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/apellaser.ro\/en\/product\/istar-340t-intensified-ccd-camera-andor\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"iStar 340T Intensified CCD camera | Andor - APEL LASER\" \/>\n<meta property=\"og:description\" content=\"Andor\u2019s iStar 340T Intensified CCD sensor series is designed to offer the ultimate integrated detection solution for high resolution, ns-scale time-resolved Spectroscopy. The high resolution 2048 x 512 array with 13.5 \u00b5m pixel size offers a 4:1 aspect ratio which is ideally suited for use with Andor\u2019s Shamrock Czerny-Turner spectrograph series and accessories.  Resources:  BrochureManufacturer\" \/>\n<meta property=\"og:url\" content=\"https:\/\/apellaser.ro\/en\/product\/istar-340t-intensified-ccd-camera-andor\/\" \/>\n<meta property=\"og:site_name\" content=\"APEL LASER\" \/>\n<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/apellaser\" \/>\n<meta property=\"article:modified_time\" content=\"2023-11-21T08:46:21+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/apellaser.ro\/wp-content\/uploads\/2023\/07\/Camera-stiintifica-iStar-340T-CCD.png\" \/>\n\t<meta property=\"og:image:width\" content=\"1000\" \/>\n\t<meta property=\"og:image:height\" content=\"866\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/png\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data1\" content=\"2 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/apellaser.ro\\\/en\\\/product\\\/istar-340t-intensified-ccd-camera-andor\\\/\",\"url\":\"https:\\\/\\\/apellaser.ro\\\/en\\\/product\\\/istar-340t-intensified-ccd-camera-andor\\\/\",\"name\":\"iStar 340T Intensified CCD camera | Andor - APEL LASER\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/apellaser.ro\\\/en\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/apellaser.ro\\\/en\\\/product\\\/istar-340t-intensified-ccd-camera-andor\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/apellaser.ro\\\/en\\\/product\\\/istar-340t-intensified-ccd-camera-andor\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/apellaser.ro\\\/wp-content\\\/uploads\\\/2023\\\/07\\\/Camera-stiintifica-iStar-340T-CCD.png\",\"datePublished\":\"2023-07-23T15:24:33+00:00\",\"dateModified\":\"2023-11-21T08:46:21+00:00\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/apellaser.ro\\\/en\\\/product\\\/istar-340t-intensified-ccd-camera-andor\\\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/apellaser.ro\\\/en\\\/product\\\/istar-340t-intensified-ccd-camera-andor\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/apellaser.ro\\\/en\\\/product\\\/istar-340t-intensified-ccd-camera-andor\\\/#primaryimage\",\"url\":\"https:\\\/\\\/apellaser.ro\\\/wp-content\\\/uploads\\\/2023\\\/07\\\/Camera-stiintifica-iStar-340T-CCD.png\",\"contentUrl\":\"https:\\\/\\\/apellaser.ro\\\/wp-content\\\/uploads\\\/2023\\\/07\\\/Camera-stiintifica-iStar-340T-CCD.png\",\"width\":1000,\"height\":866,\"caption\":\"Solu\u021bia suprem\u0103 pentru spectroscopie \u00een timp real\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/apellaser.ro\\\/en\\\/product\\\/istar-340t-intensified-ccd-camera-andor\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Prima pagin\u0103\",\"item\":\"https:\\\/\\\/apellaser.ro\\\/en\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Products\",\"item\":\"https:\\\/\\\/apellaser.ro\\\/en\\\/shop\\\/\"},{\"@type\":\"ListItem\",\"position\":3,\"name\":\"iStar 340T Intensified CCD camera | Andor\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/apellaser.ro\\\/en\\\/#website\",\"url\":\"https:\\\/\\\/apellaser.ro\\\/en\\\/\",\"name\":\"APEL LASER\",\"description\":\"INOVATIE SI PERFORMANTA DE 20 DE ANI\",\"publisher\":{\"@id\":\"https:\\\/\\\/apellaser.ro\\\/en\\\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/apellaser.ro\\\/en\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/apellaser.ro\\\/en\\\/#organization\",\"name\":\"ApelLaser\",\"url\":\"https:\\\/\\\/apellaser.ro\\\/en\\\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/apellaser.ro\\\/en\\\/#\\\/schema\\\/logo\\\/image\\\/\",\"url\":\"https:\\\/\\\/apellaser.ro\\\/wp-content\\\/uploads\\\/2023\\\/08\\\/logo-apel-laser.png\",\"contentUrl\":\"https:\\\/\\\/apellaser.ro\\\/wp-content\\\/uploads\\\/2023\\\/08\\\/logo-apel-laser.png\",\"width\":1000,\"height\":500,\"caption\":\"ApelLaser\"},\"image\":{\"@id\":\"https:\\\/\\\/apellaser.ro\\\/en\\\/#\\\/schema\\\/logo\\\/image\\\/\"},\"sameAs\":[\"https:\\\/\\\/www.facebook.com\\\/apellaser\",\"https:\\\/\\\/www.linkedin.com\\\/company\\\/apel-laser\\\/\",\"https:\\\/\\\/www.youtube.com\\\/@APELLASER-di2xf\"]}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"iStar 340T Intensified CCD camera | Andor - APEL LASER","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/apellaser.ro\/en\/product\/istar-340t-intensified-ccd-camera-andor\/","og_locale":"en_US","og_type":"article","og_title":"iStar 340T Intensified CCD camera | Andor - APEL LASER","og_description":"Andor\u2019s iStar 340T Intensified CCD sensor series is designed to offer the ultimate integrated detection solution for high resolution, ns-scale time-resolved Spectroscopy. The high resolution 2048 x 512 array with 13.5 \u00b5m pixel size offers a 4:1 aspect ratio which is ideally suited for use with Andor\u2019s Shamrock Czerny-Turner spectrograph series and accessories.  Resources:  BrochureManufacturer","og_url":"https:\/\/apellaser.ro\/en\/product\/istar-340t-intensified-ccd-camera-andor\/","og_site_name":"APEL LASER","article_publisher":"https:\/\/www.facebook.com\/apellaser","article_modified_time":"2023-11-21T08:46:21+00:00","og_image":[{"width":1000,"height":866,"url":"https:\/\/apellaser.ro\/wp-content\/uploads\/2023\/07\/Camera-stiintifica-iStar-340T-CCD.png","type":"image\/png"}],"twitter_card":"summary_large_image","twitter_misc":{"Est. reading time":"2 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/apellaser.ro\/en\/product\/istar-340t-intensified-ccd-camera-andor\/","url":"https:\/\/apellaser.ro\/en\/product\/istar-340t-intensified-ccd-camera-andor\/","name":"iStar 340T Intensified CCD camera | Andor - APEL LASER","isPartOf":{"@id":"https:\/\/apellaser.ro\/en\/#website"},"primaryImageOfPage":{"@id":"https:\/\/apellaser.ro\/en\/product\/istar-340t-intensified-ccd-camera-andor\/#primaryimage"},"image":{"@id":"https:\/\/apellaser.ro\/en\/product\/istar-340t-intensified-ccd-camera-andor\/#primaryimage"},"thumbnailUrl":"https:\/\/apellaser.ro\/wp-content\/uploads\/2023\/07\/Camera-stiintifica-iStar-340T-CCD.png","datePublished":"2023-07-23T15:24:33+00:00","dateModified":"2023-11-21T08:46:21+00:00","breadcrumb":{"@id":"https:\/\/apellaser.ro\/en\/product\/istar-340t-intensified-ccd-camera-andor\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/apellaser.ro\/en\/product\/istar-340t-intensified-ccd-camera-andor\/"]}]},{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/apellaser.ro\/en\/product\/istar-340t-intensified-ccd-camera-andor\/#primaryimage","url":"https:\/\/apellaser.ro\/wp-content\/uploads\/2023\/07\/Camera-stiintifica-iStar-340T-CCD.png","contentUrl":"https:\/\/apellaser.ro\/wp-content\/uploads\/2023\/07\/Camera-stiintifica-iStar-340T-CCD.png","width":1000,"height":866,"caption":"Solu\u021bia suprem\u0103 pentru spectroscopie \u00een timp real"},{"@type":"BreadcrumbList","@id":"https:\/\/apellaser.ro\/en\/product\/istar-340t-intensified-ccd-camera-andor\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Prima pagin\u0103","item":"https:\/\/apellaser.ro\/en\/"},{"@type":"ListItem","position":2,"name":"Products","item":"https:\/\/apellaser.ro\/en\/shop\/"},{"@type":"ListItem","position":3,"name":"iStar 340T Intensified CCD camera | Andor"}]},{"@type":"WebSite","@id":"https:\/\/apellaser.ro\/en\/#website","url":"https:\/\/apellaser.ro\/en\/","name":"APEL LASER","description":"INOVATIE SI PERFORMANTA DE 20 DE ANI","publisher":{"@id":"https:\/\/apellaser.ro\/en\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/apellaser.ro\/en\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"},{"@type":"Organization","@id":"https:\/\/apellaser.ro\/en\/#organization","name":"ApelLaser","url":"https:\/\/apellaser.ro\/en\/","logo":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/apellaser.ro\/en\/#\/schema\/logo\/image\/","url":"https:\/\/apellaser.ro\/wp-content\/uploads\/2023\/08\/logo-apel-laser.png","contentUrl":"https:\/\/apellaser.ro\/wp-content\/uploads\/2023\/08\/logo-apel-laser.png","width":1000,"height":500,"caption":"ApelLaser"},"image":{"@id":"https:\/\/apellaser.ro\/en\/#\/schema\/logo\/image\/"},"sameAs":["https:\/\/www.facebook.com\/apellaser","https:\/\/www.linkedin.com\/company\/apel-laser\/","https:\/\/www.youtube.com\/@APELLASER-di2xf"]}]}},"_links":{"self":[{"href":"https:\/\/apellaser.ro\/en\/wp-json\/wp\/v2\/product\/20143","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/apellaser.ro\/en\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/apellaser.ro\/en\/wp-json\/wp\/v2\/types\/product"}],"version-history":[{"count":4,"href":"https:\/\/apellaser.ro\/en\/wp-json\/wp\/v2\/product\/20143\/revisions"}],"predecessor-version":[{"id":23046,"href":"https:\/\/apellaser.ro\/en\/wp-json\/wp\/v2\/product\/20143\/revisions\/23046"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/apellaser.ro\/en\/wp-json\/wp\/v2\/media\/19072"}],"wp:attachment":[{"href":"https:\/\/apellaser.ro\/en\/wp-json\/wp\/v2\/media?parent=20143"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/apellaser.ro\/en\/wp-json\/wp\/v2\/product_brand?post=20143"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/apellaser.ro\/en\/wp-json\/wp\/v2\/product_cat?post=20143"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/apellaser.ro\/en\/wp-json\/wp\/v2\/product_tag?post=20143"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}